126# A disposition is recorded: release unchanged, release with shortened dating, quarantine pending further data, or rejection.{{r|whotrs961,eugdp2013}}126# A disposition is recorded: release unchanged, release with shortened dating, quarantine pending further data, or rejection.{{r|whotrs961,eugdp2013}}
127127
+128Two structural features of this sequence are worth noting. It is asymmetric in favour of rejection, because the burden is to show that quality is unaffected rather than to show that it is affected. And it depends at step 4 on data that exist only for products with a stability programme, which is why the sequence cannot be applied outside regulated distribution however carefully the temperature was recorded.{{r|ich_q1a}}
+129
128== References ==130== References ==
129{{reflist}}131{{reflist}}
148* Seevers RH, Hofer J, Harber P, Ulrich DA, Bishara R. "The use of mean kinetic temperature (MKT) in the handling, storage and distribution of temperature-sensitive pharmaceuticals." ''American Pharmaceutical Review'' (2009).150* Seevers RH, Hofer J, Harber P, Ulrich DA, Bishara R. "The use of mean kinetic temperature (MKT) in the handling, storage and distribution of temperature-sensitive pharmaceuticals." ''American Pharmaceutical Review'' (2009).
149* Parenteral Drug Association. ''Technical Report No. 39: Guidance for Temperature-Controlled Medicinal Products'', revised edition.151* Parenteral Drug Association. ''Technical Report No. 39: Guidance for Temperature-Controlled Medicinal Products'', revised edition.
+152
+153== External links ==
+154* [https://www.ich.org/ ICH Q1A(R2)] — Stability testing guideline; freely available and the basis of every labelled storage statement.
150155
151== See also ==156== See also ==