65'''Dead space.''' Volume retained in the syringe hub and needle after the plunger is fully depressed is not delivered. Reported figures range from roughly 0.02 mL for a low-dead-space insulin syringe with a fixed needle to 0.07 mL or more for a detachable-needle arrangement.{{r|whodeadspace}} Against a 0.10 mL dose that is a 20–70% loss if the syringe is not primed, which is why the dead-space field exists: entering a figure shows its effect on the number of doses the vial yields, not on the delivered dose, since a primed syringe delivers its nominal volume.65'''Dead space.''' Volume retained in the syringe hub and needle after the plunger is fully depressed is not delivered. Reported figures range from roughly 0.02 mL for a low-dead-space insulin syringe with a fixed needle to 0.07 mL or more for a detachable-needle arrangement.{{r|whodeadspace}} Against a 0.10 mL dose that is a 20–70% loss if the syringe is not primed, which is why the dead-space field exists: entering a figure shows its effect on the number of doses the vial yields, not on the delivered dose, since a primed syringe delivers its nominal volume.
6666
+67{{figure|syringe|Graduations on a 1 mL U-100 barrel. The scale reads volume; the mass it corresponds to depends entirely on the concentration in the vial.}}
+68
67== References ==69== References ==
68{{reflist}}70{{reflist}}
71<ref name="iso7886">ISO 7886-1, ''Sterile hypodermic syringes for single use — Part 1: Syringes for manual use''. International Organization for Standardization.</ref>73<ref name="iso7886">ISO 7886-1, ''Sterile hypodermic syringes for single use — Part 1: Syringes for manual use''. International Organization for Standardization.</ref>
72<ref name="whodeadspace">World Health Organization, ''WHO Guideline on the Use of Safety-Engineered Syringes'' (2015) — includes dead-space characterisation of syringe types.</ref>74<ref name="whodeadspace">World Health Organization, ''WHO Guideline on the Use of Safety-Engineered Syringes'' (2015) — includes dead-space characterisation of syringe types.</ref>
+75
+76== Further reading ==
+77* International Council for Harmonisation, ''Q6A: Specifications: Test Procedures and Acceptance Criteria for New Drug Substances and New Drug Products''.
7378
74== See also ==79== See also ==