Vial: difference between revisions
Diff·revision 11 → 12·15:09, 2 Dec 2024
Difference between revision 11 and revision 12 of Vial. 8 lines changed; the page grew by 303 bytes.
| Revision 11 — 21:53, 18 Nov 2024 RepackRadek (talk) add the collapse-temperature point, sourced 12,879 bytes +1,702 | Revision 12 — 15:09, 2 Dec 2024 PrepHPLC_Pia (talk) expand §Vials in unregulated distribution 13,182 bytes +303 | ||
|---|---|---|---|
| 1 | {{Infobox concept | 1 | {{Infobox concept |
| 2 | | name = Vial | 2 | | name = Vial |
| + | 3 | | subtitle = Primary container | |
| 3 | | image = vial.svg | 4 | | image = vial.svg |
| 4 | | caption = A tubing-drawn vial with an elastomeric closure and crimped aluminium ferrule. The three components together constitute the container closure system. | 5 | | caption = A tubing-drawn vial with an elastomeric closure and crimped aluminium ferrule. The three components together constitute the container closure system. |
| ⋮ | ⋮ | ||
| 13 | | Forming routes = Drawn from tubing; moulded | 14 | | Forming routes = Drawn from tubing; moulded |
| 14 | | Principal degradation mode = Inner-surface delamination | 15 | | Principal degradation mode = Inner-surface delamination |
| + | 16 | <!-- Applicable standards --> | |
| + | 17 | | Vials from glass tubing = ISO 8362-1 | |
| + | 18 | | Closures for injection vials = ISO 8362-2 | |
| + | 19 | | Freeze-drying closures = ISO 8362-5 | |
| + | 20 | | Elastomeric closures = USP <381> | |
| + | 21 | | Container closure integrity = USP <1207> | |
| + | 22 | | Inner-surface durability = USP <1660> | |
| 15 | }} | 23 | }} |
| 16 | {{hatnote|For containers intended for repeated withdrawal, see [[Multi-dose vial]]. For the operations that fill and close them, see [[Vial filling and stoppering]].}} | 24 | {{hatnote|For containers intended for repeated withdrawal, see [[Multi-dose vial]]. For the operations that fill and close them, see [[Vial filling and stoppering]].}} |