76National colour coding encodes the treatment route rather than the hazard. The English scheme, set out in Health Technical Memorandum 07-01 and adopted widely in the United Kingdom, is representative:76National colour coding encodes the treatment route rather than the hazard. The English scheme, set out in Health Technical Memorandum 07-01 and adopted widely in the United Kingdom, is representative:
7777
+78|+ Sharps container colour coding, Health Technical Memorandum 07-01
+79| !Lid colour | Contents | Treatment route |
+80|---|---|---|
+81| Orange | Sharps not contaminated with medicinal products | Treatment permitted before disposal |
+82| Yellow | Sharps contaminated with medicinal products other than cytotoxic or cytostatic | Incineration |
+83| Purple | Sharps contaminated with cytotoxic or cytostatic medicinal products | Incineration at a permitted facility |
+84| Blue | Medicinal waste other than sharps | Incineration |
+85| Red | Anatomical waste | Incineration |
+86
+87=== Fill limits and their rationale ===
+88The three-quarters fill convention exists to preserve headroom, so that a sharp can be dropped in without contact with the contents and so that the container closes without compression. Injury reports associated with overfilled containers describe two mechanisms: contact with protruding sharps at the aperture, and puncture through the container wall when a full container is compressed during closure or transport.{{r|epinet,iso23907}}
+89
+90The fill line is a marked feature under ISO 23907-1, which makes overfilling an observable rather than a judgement-based failure. Guidance therefore treats reaching the line as the trigger for closure regardless of elapsed time, and separately imposes a maximum period a container may remain open — commonly three months in United Kingdom practice — to limit the interval over which contents accumulate.{{r|htm0701}}
+91
78== References ==92== References ==
79{{reflist}}93{{reflist}}
87<ref name="epinet">International Safety Center. ''EPINet Sharps Injury and Blood and Body Fluid Exposure Surveillance Report'' (annual series).</ref>101<ref name="epinet">International Safety Center. ''EPINet Sharps Injury and Blood and Body Fluid Exposure Surveillance Report'' (annual series).</ref>
88<ref name="fda_sharps">US Food and Drug Administration. "Safely Using Sharps (Needles and Syringes) at Home, at Work and on Travel" — consumer and device guidance, current revision.</ref>102<ref name="fda_sharps">US Food and Drug Administration. "Safely Using Sharps (Needles and Syringes) at Home, at Work and on Travel" — consumer and device guidance, current revision.</ref>
+103
+104== See also ==
+105* [[Subcutaneous injection]]
+106* [[Insulin syringe]]
+107* [[Syringe dead space]]
+108* [[Injection site rotation]]
89109
90{{DEFAULTSORT:Sharps disposal}}110{{DEFAULTSORT:Sharps disposal}}