Cold chain: difference between revisions
Diff·revision 1 → 2·19:11, 20 Jun 2024
Difference between revision 1 and revision 2 of Cold chain. 3 lines changed; the page grew by 656 bytes.
| Revision 1 — 09:00, 19 Jun 2024 LedgerLysander (talk) create article — process stub 2,992 bytes +2,992 | Revision 2 — 19:11, 20 Jun 2024 CommaCarys (talk) add the cross-link to the temperature-excursion article 3,648 bytes +656 | ||
|---|---|---|---|
| 25 | | Excessive heat | above 40 °C | | | 25 | | Excessive heat | above 40 °C | | |
| 26 | 26 | ||
| + | 27 | Two features of this table are consequential and routinely missed. ''Controlled room temperature'' is not a synonym for whatever temperature a room happens to be; it is a specification with a permitted excursion band and a mean kinetic temperature ceiling, and a warehouse that averages 27 °C does not satisfy it. And the definitions of controlled cold and controlled room temperature both build permitted excursions into the definition itself, so a brief departure from the nominal band is not automatically an excursion in the regulatory sense — a distinction developed at [[Temperature excursion]].{{r|usp659}} | |
| + | 28 | ||
| 27 | == References == | 29 | == References == |
| 28 | {{reflist}} | 30 | {{reflist}} |
| ⋮ | ⋮ | ||
| 34 | [[Category:Cold chain and stability]] | 36 | [[Category:Cold chain and stability]] |
| 35 | [[Category:Logistics]] | 37 | [[Category:Logistics]] |
| + | 38 | [[Category:Preparation and handling]] | |