Cold chain: difference between revisions

Diff·revision 11 → 12·10:51, 4 Oct 2024

Difference between revision 11 and revision 12 of Cold chain. 2 lines changed; the page grew by 477 bytes.

Revision 11 — 23:02, 19 Sep 2024
CrossRefCleve (talk)
state that a phase-change pack and a gel pack behave differently
10,813 bytes +575
Revision 12 — 10:51, 4 Oct 2024
FmocFrancis (talk)
rm the blanket claim that excursions are harmless
11,290 bytes +477
63| Vaccine vial monitor | Cumulative heat exposure at the individual vial | Freezing exposure |63| Vaccine vial monitor | Cumulative heat exposure at the individual vial | Freezing exposure |
6464
+65The vaccine vial monitor deserves separate mention because it is attached to the individual container rather than to the shipment, and therefore survives every custody transfer. It is a heat-sensitive label whose inner square darkens progressively; when it matches or exceeds the reference ring the vial is not to be used. Its limitation is definitional: it responds to heat and not to freezing, so a vial that has been frozen presents an unchanged monitor.{{r|kartoglu2014}}
+66
65=== Calibration and traceability ===67=== Calibration and traceability ===
66A temperature record is only as good as the calibration of the instrument that produced it. Compendial guidance on monitoring devices expects calibration traceable to a national metrology institute, at intervals appropriate to the device, and at points within the range of interest rather than only at ambient temperature. A logger calibrated at 25 °C and used at 5 °C may carry an error larger than its stated accuracy.{{r|usp1118}}68A temperature record is only as good as the calibration of the instrument that produced it. Compendial guidance on monitoring devices expects calibration traceable to a national metrology institute, at intervals appropriate to the device, and at points within the range of interest rather than only at ambient temperature. A logger calibrated at 25 °C and used at 5 °C may carry an error larger than its stated accuracy.{{r|usp1118}}